Tampilkan postingan dengan label code. Tampilkan semua postingan
Tampilkan postingan dengan label code. Tampilkan semua postingan

Sabtu, 05 April 2014

Canon Error Code E101 E102 E110 E120 E121 E140 E141 E142 E143 E144 E145 E146 Eror code Canon

E101 The AF motor of the laser unit is faulty.
E102 The light intensity of the laser does not reach a specific level.
E110 The polygonal scanner motor does not reach a specific speed
within a specific time.
E111 The polygonal cooling fan does not rotate properly.
E120 The temperature of the laser does not reach a specific value.
E121 The stoppage of the laser cooling fan is detected.
E140 The movable guide motor is turned ON, and a specific position
cannot be detected within a specific time.

E141 1. The capping motor is turned ON, and a specific position cannot
be detected within a specific time.
2. A specific position of the cam sensor for the recovery system cannot be
detected within a specific time.
E142 The pressure position switching motor is turned ON, and a specific
position cannot be detected within a specific time.
E143 The intake switching motor is turned ON, and a specific position
cannot be detected within a specific time.
E144 A detection signal is not returned to the ink pump monitor after the
ink pump is activated: DCC -> BHD -> pump drive signal
E145 No signal is generated from the position sensor within a specific
time after a drive signal of the cutter motor is generated.
E146 1. The waste ink full sensor is turned ON.
2. The intake counter for waste ink exceeds a specific value.

Rabu, 26 Februari 2014

Canon Error Code E101 Canon Eror code E150 E151 E152 E153 E154 E155

E150 Neither thermistor nor trimmer resistance is connected to the head.
(The head is not connected.)
E151 The thermistor of the head is open-circuited.
E152 The thermistor of the head is short-circuited.
E153 The trimmer resistance of the head is open-circuited.
E154 The trimmer resistance of the head is short-circuited.
E155 The trimmer resistance of the head is out of specifications.
E156 When a specific voltage is applied to the head, the voltage of the
head is not changed within a specific time.
E157 The voltage of the head is out of the specifications.
E160 The temperature of the head does not reach a specific temperature
within a specific time.
E161 The temperature of the head exceeds a specific temperature.
E170 When the pulse motor for the head scan is driven, it cannot be
detected by a sensor within a specific time.
E171 The motor is not connected to the pulse motor driver PCB for the head scan.
E172 The gate array employed to drive the pulse motor for head scan is faulty.
E180 The motor is not connected to the vertical scanning pulse motor driver PCB.
E181 The gate array employed to drive the vertical scanning pulse motor is faulty.
E182 After the vertical scanning motor is driven, the phase sensor cannot be
detected within a specific time.
E183 After the registration roller cam clutch 2 is turned ON, a given
paper size cannot be detected within a specific time.
E190 RAM directly connected to CPU is faulty.
E191 An error occurs in the communication with the microcomputer (D/A
converter) for high voltage use.